前言

单盘组的RAID0做的OSD,设备上直接把这块盘拔掉,然后重新插回去,本想看看重做RAID0后,UI rescan or reformat OSD是否OK的,结果在重做RAID0期间碰到了本文的问题,记录一下。

现象

单盘RAID0被拔掉后,这块SATA盘的“Firmware State” 是 “Unconfigured(bad), Spun Up”,于是尝试make good it:

shell

root@node247:~# /opt/MegaRAID/MegaCli/MegaCli64 -PDMakeGood -PhysDrv[0:5] -a0
                                     
Adapter: 0: EnclId-0 SlotId-5 state changed to Unconfigured-Good.

Exit Code: 0x00

尝试对它重建建RAID0,结果失败,RAID卡event log显示:

导出的RAID卡的event log:

/opt/MegaRAID/MegaCli/MegaCli64 -AdpEventLog -GetEvents -f event.log -A0

shell

seqNum: 0x000153dc
Time: Mon Dec 30 10:12:20 2019

Code: 0x000000da
Class: 0
Locale: 0x40
Event Description: Foreign Configuration Detected
Event Data:
===========
None

直接Display event log:

/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL

shell

12/30/19 10:13:10: C0:EVT#87008-12/30/19 10:13:10: 218=Foreign Configuration Detected
12/30/19 10:13:11: C0:pii addBvdInfo rsvd2=1 <- bvd ld=0
12/30/19 10:13:11: C0:createMegaraidCfg: cfg:4422ac20 forCfg=441cd7e0 merge:0 import:0 other_pinned_vds:c02e1240 
12/30/19 10:13:11: C0:**** PinnedCacheDataStructures->pinned_cache_present
12/30/19 10:13:11: C0:0x00000002
12/30/19 10:13:11: C0:sscPinnedWindowInfo.ssd_window_pinned 0 
12/30/19 10:13:11: C0:createMegaraidCfg - V ld 0  targetId 1  LdMapTargetIdToLd fe totLd:1 
12/30/19 10:13:11: C0:createMegaraidCfg - VI number_pinned_vds_found_during_import 1 targetId 1 
12/30/19 10:13:11: C0:createMegaraidCfg - pii createMR1 rsvd2=1 <- forcfg ld=0 import:0 OldTargetId:1 merge:0 cfg->logDrvCount:0 ldCount:7 
12/30/19 10:13:11: C0:NumberOfVdsWithPinnedCache: number_of_pinned_vds = 1

均提示,侦测到PD Foreign 状态 Foreign Configuration Detected

解决方法

清理Foreign状态

shell

root@node247:~# /opt/MegaRAID/MegaCli/MegaCli64 -CfgForeign -Clear -a0
                                     
Failed to clear Foreign configuration 0 on controller 0.

FW error description: 
 The current operation is not allowed because the controller has data in cache for offline or missing virtual disks.  

Exit Code: 0x54
root@node247:~# 

很遗憾,报错了,究其原因,是VD直接被拔掉,VD对应的PD里还有一些cache,这些cache需要先清理掉。

再次解决之:

shell

root@node247:~# /opt/MegaRAID/MegaCli/MegaCli64  -DiscardPreservedCache -L1 -a0 
                                     
Adapter #0

Virtual Drive(Target ID 01): Preserved Cache Data Cleared.

Exit Code: 0x00
root@node247:~# /opt/MegaRAID/MegaCli/MegaCli64 -CfgForeign -Clear -aALL
                                     
Foreign configuration 0 is cleared on controller 0.

Exit Code: 0x00
root@node247:~# 

这里成功清理了对应VD的cache(虽然VD已经不存在了,但要记住这个RAID0在损坏前的VD id,这里是1),之后就可以成功创建RAID0了


来源: Transcendent
文章作者: Gavin Wang
文章链接: 解决因RAID卡提示VD有cache而无法创建RAID问题 | Transcendent