这是opendss 13节点算例, IEEE13节点算例,线路参数,负荷数据,变压器参数, 调压器参数如下:

Config.PhasingPhaseNeutralSpacing
  ACSRACSRID
601B A C N556,500 26/74/0 6/1500
602C A B N4/0 6/14/0 6/1500
603C B N1/01/0505
604A C N1/01/0505
605C N1/01/0510

 

Underground Line Configuration Data:

 

Config.PhasingCableNeutralSpace ID
606A B C N250,000 AA, CNNone515
607    A N1/0 AA, TS1/0 Cu520

 

Line Segment Data:

 

Node ANode BLength(ft.)Config.
632645500603
632633500602
6336340XFM-1
645646300603
6506322000601
684652800607
6326712000601
671684300604
6716801000601
6716920Switch
684611300605
692675500606

 

Transformer Data:

 

 kVAkV-highkV-lowR - %X - %
Substation:5,000115 - D4.16 Gr. Y18
XFM -15004.16 – Gr.W0.48 – Gr.W1.12

 

Capacitor Data:

 

NodePh-APh-BPh-C
 kVArkVArkVAr
675200200200
611  100
Total200200300

 

 

 

Regulator Data:

 

Regulator ID:1  
Line Segment:650 - 632  
Location:50  
Phases:A - B -C  
Connection:3-Ph,LG  
Monitoring Phase:A-B-C  
Bandwidth:2.0 volts  
PT Ratio:20  
Primary CT Rating:700  
Compensator Settings:Ph-APh-BPh-C
R - Setting:333
X - Setting:999
Volltage Level:122122122

 

Spot Load Data:

 

NodeLoadPh-1Ph-1Ph-2Ph-2Ph-3Ph-3
 ModelkWkVArkWkVArkWkVAr
634Y-PQ1601101209012090
645Y-PQ0017012500
646D-Z0023013200
652Y-Z128860000
671D-PQ385220385220385220
675Y-PQ4851906860290212
692D-I0000170151
611Y-I000017080
 TOTAL11586069736271135753

 

Distributed Load Data:

 

Node ANode BLoadPh-1Ph-1Ph-2Ph-2Ph-3Ph-3
  ModelkWkVArkWkVArkWkVAr
632671Y-PQ1710663811768

 

 

 

IEEE 13 NODE TEST FEEDER

Impedances

 

Configuration 601:

 

           Z (R +jX) in ohms per mile

 0.3465  1.0179   0.1560  0.5017   0.1580  0.4236

                  0.3375  1.0478   0.1535  0.3849

                                   0.3414  1.0348

          B in micro Siemens per mile

            6.2998   -1.9958   -1.2595

                      5.9597   -0.7417

                                5.6386

 

Configuration 602:

 

          Z (R +jX) in ohms per mile

0.7526  1.1814   0.1580  0.4236   0.1560  0.5017

                 0.7475  1.1983   0.1535  0.3849

                                  0.7436  1.2112

         B in micro Siemens per mile

           5.6990   -1.0817   -1.6905

                     5.1795   -0.6588

                               5.4246

 

Configuration 603:

 

           Z (R +jX) in ohms per mile

 0.0000  0.0000   0.0000  0.0000   0.0000  0.0000

                  1.3294  1.3471   0.2066  0.4591

                                   1.3238  1.3569

          B in micro Siemens per mile

            0.0000    0.0000    0.0000

                      4.7097   -0.8999

                                4.6658

 

Configuration 604:

 

           Z (R +jX) in ohms per mile

 1.3238  1.3569   0.0000  0.0000   0.2066  0.4591

                  0.0000  0.0000   0.0000  0.0000

                                   1.3294  1.3471

          B in micro Siemens per mile

            4.6658    0.0000   -0.8999

                      0.0000    0.0000

                                4.7097

 

Configuration 605:

 

           Z (R +jX) in ohms per mile

 0.0000  0.0000   0.0000  0.0000   0.0000  0.0000

                  0.0000  0.0000   0.0000  0.0000

                                   1.3292  1.3475

          B in micro Siemens per mile

            0.0000    0.0000    0.0000

                      0.0000    0.0000

                                4.5193

 

Configuration 606:

 

          Z (R +jX) in ohms per mile

0.7982  0.4463   0.3192  0.0328   0.2849 -0.0143

                 0.7891  0.4041   0.3192  0.0328

                                  0.7982  0.4463

         B in micro Siemens per mile

          96.8897    0.0000    0.0000

                    96.8897    0.0000

                              96.8897

 

Configuration 607:

 

           Z (R +jX) in ohms per mile

 1.3425  0.5124   0.0000  0.0000   0.0000  0.0000

                  0.0000  0.0000   0.0000  0.0000

                                   0.0000  0.0000

          B in micro Siemens per mile

           88.9912    0.0000    0.0000

                      0.0000    0.0000

                                0.0000

           想了解详情请下载附件http://www.apollocode.net/a/1013.html

  • 0
    点赞
  • 10
    收藏
    觉得还不错? 一键收藏
  • 1
    评论
IEEE(国际电气和电子工程师协会)是全球最大的专业技术组织之一,其发布的标准和指南被广泛应用于电气和电子工程领域。以下是IEEE常用的节点算例: 1. 计算机网络节点算例:在计算机网络中,节点是指与网络相连接的设备或主机。常见的计算机网络节点算例包括路由器、交换机、集线器、网关、服务器、个人电脑等。这些节点通过交换数据包和信息来实现网络之间的通信和数据传输。 2. 传感器网络节点算例:传感器网络是由大量采用传感器技术的节点组成的网络。每个节点都具有感知环境信息和传输数据的能力。例如,一个农田监测系统可以将传感器节点安装在不同的位置,监测土壤湿度、温度等信息,并将数据传输到中心节点进行处理和分析。 3. 物联网节点算例:物联网是连接和管理物理设备、传感器和其他物体的网络。其中的节点具有自主且智能的交流能力。例如,智能家居系统中的各个智能设备(如智能扫地机器人、智能灯泡等)可以作为物联网节点,通过互联网进行数据交换和远程控制。 4. 通信网络节点算例:在通信网络中,节点代表着网络的连接点或关键设备,用于传输和控制数据的流动。例如,移动通信网络中的基站被视为节点,用于连接移动设备与互联网。 总之,IEEE常用的节点算例包括计算机网络节点、传感器网络节点、物联网节点以及通信网络节点。这些节点在各自的应用领域中发挥着重要的作用,促进了信息的交流和数据的传输。
评论 1
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值