Oracle 小型机T7-1更换rpool中的硬盘

  1. 确定故障原因

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
root@ test  # fmadm faulty
--------------- ------------------------------------  -------------- ---------
TIME            EVENT-ID                              MSG-ID         SEVERITY
--------------- ------------------------------------  -------------- ---------
Oct 30 22:11:10 8ad90d8d-3e4f-432d-a233-84f8627dcf10  DISK-8000-0X   Major    
 
Problem Status    :  open
Diag Engine       : eft / 1.16
System
     Manufacturer  : Oracle Corporation
     Name          : SPARC T7-1
     Part_Number   : 34429612+1+1
     Serial_Number : AK00373594
     Host_ID       : 86bb603a
 
----------------------------------------
Suspect 1 of 1 :
    Problem class : fault.io.disk.predictive-failure
    Certainty   : 100%
    Affects     : dev: /// :devid=id1,sd@n5000cca02f1d2524 //scsi_vhci/disk @g5000cca02f1d2524
    Status      : faulted but still providing degraded service
 
    FRU
      Status           : faulty
      Location         :  "/SYS/DBP/HDD0"
      Manufacturer     : HGST
      Name             : H101860SFSUN600G
      Part_Number      : HGST-H101860SFSUN600G
      Revision         : A990
      Serial_Number    : 001619FJ0WNC--------03GJ0WNC
      Chassis
         Manufacturer  : Oracle Corporation
         Name          : SPARC T7-1
         Part_Number   : 34429612+1+1
         Serial_Number : AK00373594
 
Description : SMART health-monitoring firmware reported that a disk failure is
               imminent.
 
Response    : A hot-spare disk may have been activated.
 
Impact      : It is likely that the continued operation of this disk will
               result  in  data loss.
 
Action      : Use  'fmadm faulty'  to provide a  more  detailed view of this event.
               Please refer to the associated reference document at
               http: //support .oracle.com /msg/DISK-8000-0X  for  the latest service
               procedures and policies regarding this diagnosis.
root@ test  # more /var/adm/messages 
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 16:23:13 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 394604487                 Error Block: 394604487
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 17:06:27 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 118860647                 Error Block: 118860647
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 17:11:11 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 86417744                  Error Block: 86417744
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 17:36:14 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 118915795                 Error Block: 118915795
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 17:54:11 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 86417744                  Error Block: 86417744
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 19:11:49 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 211206686                 Error Block: 211206686
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:16:45 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 213848167                 Error Block: 213848167
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:21:55 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 209782185                 Error Block: 209782185
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:27:08 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 213848182                 Error Block: 213848182
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:37:29 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 211019254                 Error Block: 211019254
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:42:42 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 211955388                 Error Block: 211955388
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
Nov  8 20:58:15 zbwl03  Error  for  Command:  read (10)                Error Level: Informational
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 213894761                 Error Block: 213894761
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (<vendor unique code 0x5d>), ASCQ: 0x90, FRU: 0x90
Nov  8 21:08:38 zbwl03 scsi: [ID 243001 kern.warning] WARNING:  /scsi_vhci/disk @g5000cca02f1d2524 (sd5):
                             Serial Number: 1619FJ0WNC 
root@ test  # zpool status rpool
   pool: rpool
  state: DEGRADED
status: One or  more  devices are unavailable  in  response to persistent errors.
         Sufficient replicas exist  for  the pool to  continue  functioning  in  a
         degraded state.
action: Determine  if  the device needs to be replaced, and  clear  the errors
         using  'zpool clear'  or  'fmadm repaired' , or replace the device
         with  'zpool replace' .
         Run  'zpool status -v'  to see device specific details.
   scan: resilvered 191G  in  18m17s with 0 errors on Wed Aug 31 20:15:31 2016
 
config:
 
         NAME                       STATE     READ WRITE CKSUM
         rpool                      DEGRADED     0     0     0
           mirror-0                 DEGRADED     0     0     0
             c0t5000CCA02F1D2524d0  DEGRADED     0     0     0
             c0t5000CCA02F1D7534d0  ONLINE       0     0     0
 
errors: No known data errors

   2.具体操作步骤

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
root@ test  # zpool offline rpool c0t5000CCA02F1D2524d0
root@ test  # zpool status rpool
   pool: rpool
  state: DEGRADED
status: One or  more  devices has been taken offline by the administrator.
         Sufficient replicas exist  for  the pool to  continue  functioning  in  a
         degraded state.
action: Online the device using  'zpool online'  or replace the device with
         'zpool replace' .
   scan: resilvered 191G  in  18m17s with 0 errors on Wed Aug 31 20:15:31 2016
 
config:
 
         NAME                       STATE     READ WRITE CKSUM
         rpool                      DEGRADED     0     0     0
           mirror-0                 DEGRADED     0     0     0
             c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
             c0t5000CCA02F1D7534d0  ONLINE       0     0     0
 
errors: No known data errors
root@ test  # cfgadm -al
Ap_Id                          Type         Receptacle   Occupant     Condition
c4                             fc           connected    unconfigured unknown
c5                             fc-fabric    connected    configured   unknown
c5::2100000e1ecb1261           unknown      connected    unconfigured unknown
c5::2100000e1ecc7100           disk         connected    configured   unknown
c5::2100000e1ecc8320           disk         connected    configured   unknown
c6                             scsi-sas     connected    unconfigured unknown
c7                             scsi-sas     connected    configured   unknown
c7::w5000cca02f1d2524,0        disk-path    connected    configured   unknown
c8                             scsi-sas     connected    configured   unknown
c8::w5000cca02f1d7535,0        disk-path    connected    configured   unknown
c9                             fc           connected    unconfigured unknown
c11                            fc-fabric    connected    configured   unknown
c11::2100000e1ecb11f1          unknown      connected    unconfigured unknown
c11::2100000e1ecc8350          disk         connected    configured   unknown
c11::2100000e1ecc84c0          disk         connected    configured   unknown
usb0 /1                          unknown      empty        unconfigured ok
usb0 /2                          unknown      empty        unconfigured ok
usb0 /3                          usb-hub      connected    configured   ok
usb0 /3 .1                       usb-device   connected    configured   ok
usb0 /3 .2                       usb-communications connected    configured   ok
usb0 /3 .3                       unknown      empty        unconfigured ok
usb0 /3 .4                       unknown      empty        unconfigured ok
usb0 /4                          usb-hub      connected    configured   ok
usb0 /4 .1                       unknown      empty        unconfigured ok
usb0 /4 .2                       usb-storage  connected    configured   ok
usb0 /5                          unknown      empty        unconfigured ok
usb0 /6                          unknown      empty        unconfigured ok
usb0 /7                          usb-hub      connected    configured   ok
usb0 /7 .1                       unknown      empty        unconfigured ok
usb0 /7 .2                       unknown      empty        unconfigured ok
usb0 /7 .3                       unknown      empty        unconfigured ok
usb0 /7 .4                       unknown      empty        unconfigured ok
usb0 /8                          usb-hub      connected    configured   ok
usb0 /8 .1                       usb-device   connected    configured   ok
usb0 /8 .2                       unknown      empty        unconfigured ok

记住位置编号,unconfigure故障磁盘

1
2
c7::w5000cca02f1d2524,0
root@ test  # cfgadm -c unconfigure  c7::w5000cca02f1d2524,0

拨出故障硬盘,插入新的磁盘

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
root@ test  # cfgadm -al
Ap_Id                          Type         Receptacle   Occupant     Condition
c4                             fc           connected    unconfigured unknown
c5                             fc-fabric    connected    configured   unknown
c5::2100000e1ecb1261           unknown      connected    unconfigured unknown
c5::2100000e1ecc7100           disk         connected    configured   unknown
c5::2100000e1ecc8320           disk         connected    configured   unknown
c6                             scsi-sas     connected    unconfigured unknown
c7                             scsi-sas     connected    configured   unknown
c7::w5000cca02f1091b9,0        disk-path    connected    configured   unknown
c8                             scsi-sas     connected    configured   unknown
c8::w5000cca02f1d7535,0        disk-path    connected    configured   unknown
c9                             fc           connected    unconfigured unknown
c11                            fc-fabric    connected    configured   unknown
c11::2100000e1ecb11f1          unknown      connected    unconfigured unknown
c11::2100000e1ecc8350          disk         connected    configured   unknown
c11::2100000e1ecc84c0          disk         connected    configured   unknown
usb0 /1                          unknown      empty        unconfigured ok
usb0 /2                          unknown      empty        unconfigured ok
usb0 /3                          usb-hub      connected    configured   ok
usb0 /3 .1                       usb-device   connected    configured   ok
usb0 /3 .2                       usb-communications connected    configured   ok
usb0 /3 .3                       unknown      empty        unconfigured ok
usb0 /3 .4                       unknown      empty        unconfigured ok
usb0 /4                          usb-hub      connected    configured   ok
usb0 /4 .1                       unknown      empty        unconfigured ok
usb0 /4 .2                       usb-storage  connected    configured   ok
usb0 /5                          unknown      empty        unconfigured ok
usb0 /6                          unknown      empty        unconfigured ok
usb0 /7                          usb-hub      connected    configured   ok
usb0 /7 .1                       unknown      empty        unconfigured ok
usb0 /7 .2                       unknown      empty        unconfigured ok
usb0 /7 .3                       unknown      empty        unconfigured ok
usb0 /7 .4                       unknown      empty        unconfigured ok
usb0 /8                          usb-hub      connected    configured   ok
usb0 /8 .1                       usb-device   connected    configured   ok
usb0 /8 .2                       unknown      empty        unconfigured ok
root@ test  # cfgadm -c configure  c7::w5000cca02f1091b9,0
root@ test  # format
Searching  for  disks... done
 
 
AVAILABLE DISK SELECTIONS:
        0. c0t5000CCA02F1091B8d0 <HGST-H101860SFSUN600G-A990-558.91GB>  solaris
           /scsi_vhci/disk @g5000cca02f1091b8
           /dev/chassis/SYS/DBP/HDD0/disk
        1. c0t5000CCA02F1D7534d0 <HGST-H101860SFSUN600G-A990-558.91GB>
           /scsi_vhci/disk @g5000cca02f1d7534
           /dev/chassis/SYS/DBP/HDD1/disk
        2. c2t0d0 <MICRON-eUSB DISK-1112 cyl 246 alt 0 hd 255 sec 63>
           /pci @300 /pci @2 /usb @0 /hub @4 /storage @2 /disk @0,0
           /dev/chassis/SYS/MB/EUSB-DISK/disk
        3. c0t6000B08414B303033373335353600004d0 <Oracle-Oracle FS1-2-6203-800.83GB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600004
        4. c0t6000B08414B303033373335353600005d0 <Oracle-Oracle FS1-2-6203-800.83GB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600005
        5. c0t6000B08414B303033373335353600003d0 <Oracle-Oracle FS1-2-6203-2.00TB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600003
        6. c0t6000B08414B303033373335353600000d0 <Oracle-Oracle FS1-2-6203-2.00TB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600000
        7. c0t6000B08414B303033373335353600001d0 <Oracle-Oracle FS1-2-6203-2.00TB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600001
        8. c0t6000B08414B303033373335353600002d0 <Oracle-Oracle FS1-2-6203-2.00TB>
           /scsi_vhci/ssd @g6000b08414b303033373335353600002
        9. c0t6000B08414B303033373335353600006d0 <Oracle-Oracle FS1-2-6203 cyl 575 alt 2 hd 128 sec 32>
           /scsi_vhci/ssd @g6000b08414b303033373335353600006
Specify disk (enter its number): ^C
root@ test  # zpool help replace
usage:
         replace [-f] <pool> <device> [new-device]
root@ test  # zpool replace rpool c0t5000CCA02F1D2524d0 c0t5000CCA02F1091B8d0
Make sure to wait  until  resilver is  done  before rebooting.
root@zbwl03  # zpool status rpool
   pool: rpool
  state: DEGRADED
status: One or  more  devices is currently being resilvered.  The pool will
         continue  to  function  in  a degraded state.
action: Wait  for  the resilver to complete.
         Run  'zpool status -v'  to see device specific details.
   scan: resilver  in  progress since Tue Nov 14 10:38:00 2017
     74.5G scanned out of 165G at 2.87G /s , 31s to go
     0 resilvered
config:
 
         NAME                         STATE     READ WRITE CKSUM
         rpool                        DEGRADED     0     0     0
           mirror-0                   DEGRADED     0     0     0
             replacing-0              DEGRADED     0     0     0
               c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
               c0t5000CCA02F1091B8d0  DEGRADED     0     0     0  (resilvering)
             c0t5000CCA02F1D7534d0    ONLINE       0     0     0
 
errors: No known data errors
root@ test  # zpool status rpool
   pool: rpool
  state: DEGRADED
status: One or  more  devices is currently being resilvered.  The pool will
         continue  to  function  in  a degraded state.
action: Wait  for  the resilver to complete.
         Run  'zpool status -v'  to see device specific details.
   scan: resilver  in  progress since Tue Nov 14 10:38:00 2017
     165G scanned
     34.4G resilvered at 183M /s , 20.91%  done , 12m08s to go
config:
 
         NAME                         STATE     READ WRITE CKSUM
         rpool                        DEGRADED     0     0     0
           mirror-0                   DEGRADED     0     0     0
             replacing-0              DEGRADED    14     0     0
               c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
               c0t5000CCA02F1091B8d0  DEGRADED     0     0     0  (resilvering)
             c0t5000CCA02F1D7534d0    ONLINE       0     0     0
 
errors: No known data errors
root@ test  # zpool status rpool
   pool: rpool
  state: DEGRADED
status: One or  more  devices is currently being resilvered.  The pool will
         continue  to  function  in  a degraded state.
action: Wait  for  the resilver to complete.
         Run  'zpool status -v'  to see device specific details.
   scan: resilver  in  progress since Tue Nov 14 10:38:00 2017
     165G scanned
     161G resilvered at 157M /s , 97.98%  done , 21s to go
config:
 
         NAME                         STATE     READ WRITE CKSUM
         rpool                        DEGRADED     0     0     0
           mirror-0                   DEGRADED     0     0     0
             replacing-0              DEGRADED    14     0     0
               c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
               c0t5000CCA02F1091B8d0  DEGRADED     0     0     0  (resilvering)
             c0t5000CCA02F1D7534d0    ONLINE       0     0     0
 
errors: No known data errors
root@ test  # zpool status rpool
   pool: rpool
  state: DEGRADED
   scan: resilvered 165G  in  19m26s with 0 errors on Tue Nov 14 10:57:26 2017
 
config:
 
         NAME                         STATE     READ WRITE CKSUM
         rpool                        DEGRADED     0     0     0
           mirror-0                   DEGRADED     0     0     0
             replacing-0              DEGRADED    14     0     0
               c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
               c0t5000CCA02F1091B8d0  ONLINE       0     0     0
             c0t5000CCA02F1D7534d0    ONLINE       0     0     0
 
errors: No known data errors
root@ test  # zpool status rpool
   pool: rpool
  state: ONLINE
   scan: resilvered 165G  in  19m26s with 0 errors on Tue Nov 14 10:57:26 2017
 
config:
 
         NAME                       STATE     READ WRITE CKSUM
         rpool                      ONLINE       0     0     0
           mirror-0                 ONLINE       0     0     0
             c0t5000CCA02F1091B8d0  ONLINE       0     0     0
             c0t5000CCA02F1D7534d0  ONLINE       0     0     0
 
errors: No known data errors
root@ test  #


























本文转自lq201151CTO博客,原文链接:http://blog.51cto.com/liuqun/1981726 ,如需转载请自行联系原作者


评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值