x射线 相衬成像 matlab模拟,空间相干与入射光子能量对临床类同轴X射线相衬成像影响...

[1]POGANY A,GAO D,WILKINS S W.Contrast and resolution in imaging with a microfocus X-ray source[J].Review of Scientific Instruments,1997,68(7):2774-2782.

[2]MOMOSE A,TAKEDA T,ITAI Y.Phase-contrast x-ray computed tomography for observing biological specimens and organic materials[J].Review of Scientific Instruments,1995,66(2):1434-1436.

[3]YONEYAMA A,TAKEDA T,TSUCHIYA Y,et al.Coherence-contrast X-ray imaging based on X-ray interferometry[J].Applied Optics,2005,44(16):3258-3261.

[4]PFEIFFER F,BUNK O,DAVID C,et al.High-resolution brain tumor visualization using three-dimensional X-ray phase contrast tomography[J].Physics in  Medicine and  Biology,2007,52:6923-6930.

[5]DAVIS T J,GAO D,GUREYEV T E,et al.Phase contrast imaging of weakly absorbing materials using hard X-rays[J].Nature,1995,373(16):595-598.

[6]KOBAYASHI K,IZUMI K,KIMURA H,et al.X-ray phase-contrast imaging with submicron resolution by using extremely asymmetric Bragg diffractions[J].Applied Physics Letters,2001,78(1):132-134.

[7]MENK R H,RIGON L,ARFELLI F.Diffraction-enhanced X-ray medical imaging at the ELETTRA synchrotron light source[J].Nuclear Instruments and Methods in Physics Research Secti A,2005,548:213-220.

[8]GUIGAY J P,PAGOT E,CLOETENS P.Fourier optics approach to X-ray analyzer-based imaging[J].Opt Commun,2007,270(2):180-188.

[9]WU Xi-zeng,LIU Hong.A general theoretical formalism for X-ray phase contrast imaging[J].Journal of X-ray Science and Technology,2003,11(1):33-42.

[10]GUREYEV T E,NESTERETS Y I,PAGANIN D M,et al.Effects of incident illumination on in-line phase-contrast imaging[J].JOSA A,2006,23(1):34-42.

[11]WU Xi-zeng,LIU Hong.Clinical implementation of X-ray phase contrast imaging:theoretical foundation and design consideration[J].Medical Physics,2003,30(8):2169-2179.

[12]ZHANG Xue-long,LIU Song,HUANG Yong,et al.Optimal Contrast for X-ray Phase-contrast imaging.Acta Photonica Sinica,2008,37(6):1217-1220.

[13]XIA Tian,ZHANG Xue-long,ZHANG Guo-ying.Analysis of the absorption and the phase-effect on micro-focus X-PCI[J].Acta Photonica Sinica,2009,38(10):2516-2160.

[14]WU X Z,DEAN A,LIU H.X-ray diagnostic techniques biomedical photonics handbook[M].Tampa,FL:CRC Press,2003:1116.

[15]SNIGIREV A,SNIGIREVA I,KOHN V,et al.On the possibilities of X-ray phase contrast microimaging by coherent high-energy synchrotron radiation[J].Scientific Instruments,1995,66(12):5486-5492.

[16]WILKINS S,GUREYEV T,GAO D,et al.Phase-contrast imaging using polychromatic hard x-rays[J].Nature,1996,384(28):335-338.

[17]BORN M,WOLF E.Principles of optics:electromagnetic theory of propagation,interference and diffraction of light[M].7th ed.Cambridge,England:Cambridge University Press,1999.

[18]ATTWOOD D T.Soft X-ray and extreme ultraviolet radiation:principles and application[M].Cambridge:Cambridge University Press,1999.

[19]WU X Z,LIU H,YAN A.Optimization of X-ray phase-contrast imaging based on in-line holography[J].Nuclear Instruments and  Methods in Physics Research Section B,2005,234(4):563-572.

[20]WU X Z,LIU H.An experimental method of determining relative phase- contrast factor for X-ray imaging systems[J].Medical Physics,2004,31:997-1002.

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值