spo2数据集_NorthCARDS数据集中COVID-19 ARDS的低氧血症和呼吸系统力学的轨迹

Trajectories of Hypoxemia & Respiratory System Mechanics of COVID-19 ARDS in the NorthCARDS dataset

Rationale: The preliminary reports of COVID Acute Respiratory Distress Syndrome (COVIDARDS) suggest the existence of a subset of patients with higher lung compliance despite profound hypoxemia. Understanding heterogeneity seen in patients with COVIDARDS and comparing to non-COVIDARDS may inform tailored treatments.

Objectives: To describe the trajectories of hypoxemia and respiratory compliance in COVIDARDS and associations with outcomes. Methods: A multidisciplinary team of frontline clinicians and data scientists created the Northwell COVIDARDS dataset (NorthCARDS) leveraging over 11,542 COVID-19 hospital admissions. Data was summarized to describe differences based on clinically meaningful categories of lung compliance, and compared to non-COVIDARDS reports. A sophisticated method of extrapolating PaO2 from SpO2, as well estimating FiO2 from non invasive oxygen delivery devices were utilized to create meaningful trends of derived PaO2 to FiO2 (P/F). Measurements and Main Results: Of the 1595 COVIDARDS patients in the NorthCARDS dataset, there were 538 (34.6%) who had very low lung compliance (<20ml/cmH2O), 982 (63.2%) with low-normal compliance (20-50ml/cmH2O), and 34 (2.2%) with high lung compliance (>50ml/cmH2O). The very low compliance group had double the median time to intubation compared to the low-normal group (107 hours(IQR 26.3, 238.3) vs. 37.9 hours(IQR 4.8, 90.7)). Oxygenation trends have improved in all groups after a nadir immediately post intubation. The P/F ratio improved from a mean of 109 to 155, with the very low compliance group showing a smaller improvement compared to low compliance group. The derived P/F trends closely correlated with blood gas analysis driven P/F trends, except immediately post intubation were the trends diverge as illustrated in the image. Overall, 67.5% (n=1049) of the patients died during the hospitalization. In comparison to non-COVIDARDS reports, there were less patients in the high compliance category (2.2%vs 12%, compliance equal or over 50mL/cmH20), and more patients with P/F less than 150 ( 57.8% vs. 45.6%). No correlation was apparent between lung compliance and P/F ratio. The Oxygenation Index was similar, (11.12(SD 5.67)vs 12.8(SD 10.8)). Conclusions: Heterogeneity in lung compliance is seen in COVIDARDS, without apparent correlation to degree of hypoxemia. Notably, time to intubation was greater in the very low lung compliance category. Understanding ARDS patient heterogeneity must include consideration of treatment patterns in addition to trajectories of change in patient-level data and demographics.

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值