站点地址=用户设置的配置站点地址DOut Len是具有S1、S2和S3值的输出字节总数是指向SPC3芯片中的3个输出缓冲器的指针。DIn-Len是输入字节的总数,其中S1、S2和S3的值为指向SPC3芯片中的3个输入缓冲器的指针。Diag1Len应始终为6,以表示诊断的最小数量字节和S=SPC3芯片中指向该数据的指针。Diag2Len是扩展的诊断缓冲区长度,S是指向该数据的指针在SPC3芯片中。Aux1-Len:(参见SPC3规范),S是指向SPC3中该数据的指针炸薯条Aux2-Len:(参见SPC3规范),S是指向SPC3中该数据的指针炸薯条SSA-Len未使用,应为0,其指针S为N/A。Param Len=从设备的参数数据长度,S为SPC3芯片中指向数据的指针。Cfg Len是以S为指针的从设备的配置长度。RCfg-len是以S为指针从主机接收的。Ident是模块的PROFIBUS标识号。FDL SAP最后一个PTR是SPC3芯片中所有PDPS数据的结束。此值必须小于0xFF,否则存在内存溢出问题!通信故障模式是配置文件中的通信故障模式输入和输出数据。
Caution: Some of the commands available to you from this menu are designed for advanced debugging and system testing only, and can cause the module to stop communicating with the processor or with other devices, resulting in potential data loss or other failures. Only use these commands if you are specifically directed to do so by ProSoft Technology Technical Support staff. Some of these command keys are not listed on the menu, but are active nevertheless. Please be careful when pressing keys so that you do not accidentally execute an unwanted command.