The SPC3 is able to identify the baud rate automatically. The "baud search" state
is located after each RESET and also after the watchdog (WD) timer has run out
in the "Baud_Control_state." As a rule, SPC3 begins the search for the set rate
with the highest baud rate. If no SD1 telegram, SD2 telegram, or SD3 telegram
was received completely and without errors during the monitoring time, the
search continues with the next lowest baud rate.
After identifying the correct baud rate, SPC3 switches to the "Baud_Control"
state and monitors the baud rate. The monitoring time can be parameterized
(WD_Baud_Control_Val). The watchdog works with a clock of 100 Hz (10
milliseconds). The watchdog resets each telegram received with no errors to its
own station address. If the timer runs out, SPC3 again switches to the baud
search state.
SPC3能够自动识别波特率。“波特率搜索”状态位于每次复位之后以及看门狗(WD)计时器用完之后在“Baud_Control_state”中。通常,SPC3开始搜索设置的速率具有最高波特率。如果没有SD1电报、SD2电报或SD3电报在监控时间内完全接收到并且没有错误搜索继续到下一个最低波特率。确定正确的波特率后,SPC3切换到“baud_Control”状态并监视波特率。监控时间可以参数化(WD_Baud_Control_Val)。看门狗的时钟为100赫兹(10毫秒)。看门狗将收到的每个没有错误的电报重置为其自己的电台地址。如果计时器用完,SPC3将再次切换到波特搜索状态。波特率监测在“baud_Control”中不断监控定位的波特率看门狗是将每个无错误电报重置为其自己的站地址。监测时间乘以“WD_Baud_Control_Val”的结果(用户设置参数)通过时基(10ms)。如果监视时间用完,WD_SM再次转到“Baud_Search”。如果用户执行DP协议(DP_Mode=1,请参阅模式寄存器0)与SPC3,看门狗用于“DP_Control”状态,在接收到“Set_Param电报”时启用了响应时间监控'WD_On=1'看门狗计时器保持在波特率监控状态当存在关闭的“WD_On=0”主监控时。PROFIBUS DP当计时器用完时,状态机也不会重置。也就是说,奴隶例如,保持在DATA_Exchange状态。