SSD
MegaCli -PDlist -aAll | grep -i "Media Error Count"
MegaCli -PDlist -aAll | grep -i "Predictive Failure Count"
MegaCli -PDlist -aAll | grep -i "Other Error Count"
perccli /c0/eall/sall show all | grep -i "Media Error Count"
perccli /c0/eall/sall show all | grep -i "Predictive Failure Count"
perccli /c0/eall/sall show all | grep -i "Other Error Count"
perccli /c0 show termlog > /tmp/raid/termlog.txt
perccli /c0 show events > /tmp/raid/events.txt
perccli /c0 show all > /tmp/raid/all.txt
perccli /c0 show alilog> /tmp/raid/alilog.txt
perccli /c0/vall show all> /tmp/raid/vall.txt
查看是否有不为0的,如何有执行下面语句
MegaCli -PDlist -aAll | grep -C30 -i "Media Error Count: 错误数"
MegaCli -PDlist -aAll | grep -C30 -i "Predictive Failure Count: 错误数"
MegaCli -PDlist -aAll | grep -C30 -i "Other Error Count: 错误数"
Media Error Count:磁盘存在错误,可能是磁盘有坏道。值越大,越危险。根据磁盘状况,一般大于100报修更换。
Predictive Failure Count:磁盘的预警数。一般大于0,就报修更换。
Last Predictive Failure Event Seq Number:最后一条预警的时间序列号,这个值不为0,肯定Predictive FailureCount也不为0。
NVME
nvme list
nvme smart-log /dev/nvme0n1