本文演示获取风管连接器的属性信息。
using Autodesk.Revit.Attributes;
using Autodesk.Revit.DB;
using Autodesk.Revit.DB.Mechanical;
using Autodesk.Revit.UI;
using Autodesk.Revit.UI.Selection;
using System.Windows.Forms;
namespace RevitAddin4
{
[TransactionAttribute(TransactionMode.Manual)]
public class RevitAddin : IExternalCommand
{
public Result Execute(ExternalCommandData commandData, ref string message, ElementSet elements)
{
UIDocument uiDoc = commandData.Application.ActiveUIDocument;
Document doc = uiDoc.Document;
Selection selection = uiDoc.Selection;
Reference reference = selection.PickObject(ObjectType.Element);
Duct duct = doc.GetElement(reference) as Duct;
if (duct == null)
{
TaskDialog.Show("错误", "不是duct");
return Result.Failed;
}
ConnectorSet connectorSet = duct.ConnectorManager.Connectors;
string info = "";
foreach (var item in connectorSet)
{
Connector connector = item as Connector;
info += "Id = " + connector.Id.ToString() + "\n";
info += "Height = " + connector.Height.ToString() + "\n";
info += "Width = " + connector.Width.ToString() + "\n";
info += "Shape = " + connector.Shape.ToString() + "\n";
info += "Origin = " + connector.Origin.ToString() + "\n";
info += "\n";
}
MessageBox.Show(info);
return Result.Succeeded;
}
}
}
执行结果: