1 OSAgeingTool
For S3/S4/Warm Boot/Cold Boot Use
2. MainForm
Use Ctrl + Alt and click right down button to Open Engineer mode
3. Engineer mode
1 Test Item
S3 .S4.Cold Boot. Warm Boot can be choose
2 Count down before Test
Must > 10s
3 Sleep Time
Must > 20s
4 Execute Count
Must >=0 and <=1000
Check devicelist
If this check box is checked, tool will compare all Device list every cycle
Check device error
If this check box is checked, tool will stop when error happen
Check Use Time
no use
Check device AlwaysPhotograph
If this check box is checked ,If this testfailed, tool will prtsc all screen to log folder
AutoWarning
If this check box is checked ,if there is device error before test start ,tool will auto waring user
Check error message
not use
mordenStandby
not use
RTC coldboot
not use
powerbutton wake
not use
auto run
If this check box is checked, tool will start after save plan
auto exit
If this check box is checked, tool will close after finish test
stop on fail
If this check box is checked, tool will stop after one fail
If this check box is not checked, tool will log failed and go on when test failed ,
auto execute other program when test finish
If this check box is checked, tool start other progaram in path line
You can click Save and Exit button to save configuration
IgnorTest
xx;yyy
if you failed on special device ; you can add device to this ,then ignor the devcie ,avoid fail
for example
aaa,bbbb ,then aaa ,bbbb device will be ignor
4. How to use OSAgeingTool
Double click Start Button to start test
If you want to suspend test
You can double click Stop button then choose No
And double click Continue button to Continue test
If you want to suspend test
You can double click Stop button then choose Yes ,and report is generate
You can click View Test Report button to view Test Report
You can click View Test Log button to view Test Error Log (only Error Log)
3 You can click View Test Plan button to view Test Plan