Fundus 01
2018 Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs
Conclusion:
automated classification and detection of referable glaucomatous optic neuropathy (GON) from monoscopic color fundus photographs.(monoscopic optic disc photographs provide an equal diagnostic accuracy for glaucoma when compared with stereoscopic photographs.)
样本大,数据精细 48116 fundus photographs ( 40116 train,8000 validation)
evalution:AUC(The area under receiver opterator characteristic curve) with sensitivity and specificity
results: AUC 0.986 with sensitivity 95.6% specificity 92% | FN(87) FP(480) (还总结出高度近视或病理性近视并存是导致假阴性结果的最常见原因。physiologic cupping和病理性近视是假阳性最常见的原因)
讲了很多前期数据医生的挑选,以及最后FP、FN结果的分析。没怎么讲deep learning
Methods
研究从La