Process Control Instrumentation Technology (Chapter 11)
11.2A type-J TC with a reference monitors a process temperature. Design a twoalarm system turning on one LED at and another at .11.3Design a two-position digital controller using the force transducer of Problem 11.1 . The output should go high a...原创 2021-10-30 14:41:34 · 651 阅读 · 0 评论 -
Process Control Instrumentation Technology (Chapter 10)
10.5Design a two-position controller that provides an output of 5 V when a type-J TC junction reaches and drops to a low of 0 V when the temperature has fallen to . Assume a reference.10.6Figure 10.20 shows a drying oven for which the ov...原创 2021-11-02 21:23:06 · 836 阅读 · 0 评论 -
Process Control Instrumentation Technology ( Chapter 9 )
9.3A velocity control system has a range of 220 to 460 . If the setpoint is 327 and the measured value is , calculate the error as percentage of span.9.5A 5-m-diameter cylindrical tank is emptied by a constant outflow of . A two-position con...原创 2021-10-23 15:51:10 · 763 阅读 · 0 评论 -
Process Control Instrumentation Technology (Chapter 7)
7.1A 4- to 20 -mA control signal is loaded by a resistor and must produce a 20- to 40-V motor drive signal. Find an equation relating the input current to the output voltage.Soluting:7.5Modify Problem 7.4 by using a DIAC with a bre...原创 2021-10-17 21:39:05 · 822 阅读 · 0 评论 -
Process Control Instrumentation Technology (Chapter 6)
6.9A CdS cell has a time constant of 73 ms and a dark resistance of 150 . A light pulse that is only in length strikes the cell. If the intensity of the light pulse is such that the final resistance would be , plot the resistance versus time for ...原创 2021-10-10 20:14:50 · 825 阅读 · 0 评论 -
Process Control Instrumentation Technology (Chapter 4)
4.3 Contertinto K and4.9Use the values of RTD resistance versus temperature shown in the table to find the equations for the linear and quadratic approximations of resistance between 100°C and 130°C. Assume . What is the error in percent between ta...原创 2021-10-08 19:39:01 · 1108 阅读 · 0 评论 -
Process Control Instrumentation Technology (Chapter 3)
3.19 A 12 bit bipolar DAC has a 10.00-V reference.a. What output voltage results from digital inputs of 4A6H, 02BH, and D5DH?b. An output of 4.740 V is needed. What digital input would come closest to this value? By what percentage is the actual output原创 2021-09-21 16:33:01 · 963 阅读 · 0 评论 -
Process Control Instrumentation Technology (Chapter 2)
2.3 A sensor resistance varies from 520 to 2500. This is used for in the divider of Figure 2.4, along with and. Find:(a) the range of the divider voltage,(b) the range of power dissipation by the sensor.2.9 A bridge circuit is used with...原创 2021-09-15 15:32:13 · 1033 阅读 · 0 评论 -
Process Control Instrumentation Technology (Chapter 1)
1.3 Consturct a block diagram of a refrigerator control system.Define each block in terms of the refrigerator components.1.6 The Second cyclic transient error peak of a response test measures 4.4%.For the quarter-amplitudecriteria,what error should..原创 2021-09-07 20:17:41 · 1342 阅读 · 0 评论