请阅读【Arm® DynamIQ™ Shared Unit-120 专栏 】
文章目录
DSU-120 Utility bus
在 DSU-120 中 utility bus提供了对系统中各种组件的控制寄存器的访问通道,其中包括在cluster中 core 的控制寄存器。 utility bus是基于 64-bit AMBA AXI5 实现的的slave 接口。
utility bus 提供对下面系统组件的控制:
- Power Policy Unit (PPU) registers for the cluster and each of the cores
- Cluster control registers, including the L3 cache power-related monitors
- Reliability, Availability, and Serviceability (RAS) registers for the cores and cluster
- Memory Partitioning and Monitoring (MPAM) registers for the cluster
- Activity Monitor Unit (AMU) registers in the cores and cluster
- Max Power Mitigation Mechanism (MPMM)