EEGLAB上有人问了关于基线去除和ICA的问题,以及其他人员回答的答案,贴过来
My questions can be outlined as follows:
Q:1)Why should we first remove major artifacts and then filter the data?Can
we invert these two procedures?
A:1) Removing major artifacts, such a large spikes in the data, before
filtering can be preferable since filtering can "spread" the artifact out
over "good" data, requiring more data to be rejected after filtering. When
you remove major artifacts, and "boundary" event replaces the removed data.
Filtering is only applied to continuous data segments, not across
boundaries.
Q:2)ICA should be conducted in epoched data or continuous data?If both are
ok,which is better?For continuous data often contains large amounts of
artifacts,which happens during the interval of each trial in experiment,I
think it may be better to