欧规
(IEC
标准
)
与美规
(UL
标准
)
保险管熔断时间表
:
一
.
快熔断
美规
(UL
标准
)..
ELECTRICAL CHARACTERISTICS:
I
nf
or I
f
110% of I
n
135% of I
n
200% of I
n
I
n
Min.
Max.
Max.
50mA
–
6.3A
4 hrs
60min
2min
I
n
= Rated Current, I
f
= Fusing Current, I
nf
= Non-Fusing Current
Pre-arcing time/current characteristics at T
a
= 23
C
欧规
(IEC
标准
)
ELECTRICAL CHARACTERISTICS:
I
nf
or I
f
150% of I
n
210% of I
n
275% of I
n
400% of I
n
1000% of I
n
I
n
Min.
Max.
Min.
Max.
Min.
Max.
Max.
32mA
–
100mA
60min
30min
10ms
500ms
3ms
100ms
20ms
125mA
–
10A
60min
30min
50ms
2s
10ms
300ms
20ms
I
n
= Rated Current, I
f
= Fusing Current, I
nf
= Non-Fusing Current
Pre-arcing time/current characteristics at T
a
= 23
C
二
.
慢熔断
美规
(UL
标准
)
ELECTRICAL CHARACTERISTICS:
I
nf
or I
f
110% of I
n
135% of I
n
200% of I
n
I
n
Min.
Max.
Max.
Min
80mA - 3A
4 hrs
60min
120s
5s
3.15A
–
10A
4 hrs
60min
120s
12s
I
n
= Rated Current, I
f
= Fusing Current, I
nf
= Non-Fusing Current
Pre-arcing time/current characteristics at T
a
= 23
C
欧规
(IEC
标准
)
ELECTRICAL CHARACTERISTICS:
I
nf
or I
f
150% of I
n
210% of I
n
275% of I
n
400% of I
n
1000% of I
n