1.安装storcli:
# yum install storcli
安装后在/opt/Mega/stocli目录下
2.参数定义:
/cx = Controller ID
/vx = Virtual Drive Number
/ex = Enclosure ID
/sx = Slot ID
3.为了方便使用,可建立软链接
# ln -s /opt/MegaRAID/storcli/storcli64 /bin/storcli
# ln -s /opt/MegaRAID/storcli/storcli64 /sbin/storcli
若不想建立软链接,可在/opt/MegaRAID/stocli目录下执行./storcli64指令
4.查看当前设备raid控制器相关信息
# ./stocli64 show all
CLI Version = 007.1316.0000.0000 Mar 12, 2020
Operating system = Linux 4.19.90
Status Code = 0
Status = Success
Description = None
Number of Controllers = 1
Host Name = localhost.localdomain
Operating System = Linux 4.19.90
System Overview :
===============
------------------------------------------------------------------------------
Ctl Model Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth
------------------------------------------------------------------------------
0 RAID730-8i2GBFlash 8 2 0 0 0 0 N/A On - Y 4 Opt 【只看到一个控制器】
------------------------------------------------------------------------------
Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
PDs=Physical drives|DNOpt=Array NotOptimal|VNOpt=LD NotOptimal|Opt=Optimal
Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Spare Drive
Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit/CV
Hlth=Health|Safe=Safe-mode boot
ASO :
===
----------------------------------------------------
Ctl Cl SAS MD R6 WC R5 SS FP Re CR RF CO CW HA SSHA
----------------------------------------------------
0 X U X U U U U U X X X X X X X
----------------------------------------------------
Ctl=Controller Index|Cl=Cluster|MD=Max Disks|WC=Wide Cache|SS=Safe Store|FP=Fast Path
Re=Recovery|CR=CacheCade(Read)|RF=Reduced Feature Set|CO=Cache Offload
CW=CacheCade(Read/Write)|X=Not Available/Not Installed|U=Unlimited|T=Trial
|HA=High Availability |SSHA=Single server High Availability
5.查看控制器c0的相关信息
# ./storcli64 /c0 show
Generating detailed summary of the adapter, it may take a while to complete.
CLI Version = 007.1316.0000.0000 Mar 12, 2020
Operating system = Linux 4.19.90
Controller = 0
Status = Success
Description = None
Product Name = RAID 730-8i 2GB Flash
Serial Number = SK940709
SAS Address = 500605b00f2caa30
PCI Address = 01:09:00:00
System Time = 01/29/2021 10:35:35
Mfg. Date = 10/04/19
Controller Time = 01/29/2021 02:35:35
FW Package Build = 24.21.0-0140
BIOS Version = 6.36.00.3_4.19.08.00_0x06180204
FW Version = 4.680.00-8539
Driver Name = megaraid_sas
Driver Version = 07.706.03.00-rc1
Vendor Id = 0x1000
Device Id = 0x5D
SubVendor Id = 0x1D49
SubDevice Id = 0x608
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 9
Device Number = 0
Function Number = 0
Domain ID = 1
JBOD Drives = 2
JBOD LIST :
=========
----------------------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------------------------------
8:0 9 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035 03X4440 LENOVO U -
8:9 12 JBOD - 3.638 TB SATA HDD N N 512B TOSHIBA MG04ACA400E U -
----------------------------------------------------------------------------------------------------
ID=JBOD Target ID|EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|Onln=Online|
Offln=Offline|Intf=Interface|Med=Media Type|SeSz=Sector Size
Physical Drives = 2【2个物理磁盘】
PD LIST :
=======
----------------------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------------------------------
8:0 9 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035 03X4440 LENOVO U -
8:9 12 JBOD - 3.638 TB SATA HDD N N 512B TOSHIBA MG04ACA400E U -
----------------------------------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=Rebuild
Enclosures = 2
Enclosure LIST :
==============
-----------------------------------------------------------------------------------------------------
EID State Slots PD PS Fans TSs Alms SIM Port# ProdID VendorSpecific
-----------------------------------------------------------------------------------------------------
8 OK 12 2 1 0 3 1 0 Port 0 - 3 & Port 4 - 7 x8 380-23710-3001 0.0.12.10-0.16.0.9
252 OK 8 0 0 0 0 0 1 - SGPIO
-----------------------------------------------------------------------------------------------------
EID=Enclosure Device ID |PD=Physical drive count |PS=Power Supply count|
TSs=Temperature sensor count |Alms=Alarm count |SIM=SIM Count ||ProdID=Product ID