微通道降膜吸收实验和模拟研究。矩形通道,里面有改进。可以提高降膜吸收传质系数。
The interphase mass transfer in a falling film microchannel relies on the liquid-phase mass transfer behavior. Flow in a liquid film is predominantly laminar, and the liquid mass transfer is usually controlled by molecular diffusion. Micro-mixing structures were designed and configured in a double-side falling film microchannel, and the liquid side mass transfer was enhanced by fluid mixing and surface renewal. Computational fluid dynamics approach was used to simulate the falling film flow and mass transfer behavior with and without micro-mixing structures. The impact of the micro-mixing structures on the liquid side mass transfer coefficient was systematically investigated via CO2 absorption experiments in water. The results showed that the fluid flow and mixing was improved by staggered flow mode with micro-mixing structures in the falling film microchannels. Three flow patterns are observed inside the liquid film, i