一、问题描述

orcad画原理图调入元件时需要修改元件信息,发现其中有一行device属性不知道起什么作用,而且现在导网表时候会出现 [ALG0013] Conflicting values of following Component Definition properties found on LED_R7 and LED_R1 for part "SMD_R_0603". VALUE

二、官方给出的答案

Description: The DEVICE property that was used in previous releases, is used differently in Capture 14.0 and later. However, the existence of this property in your design library can cause problems with the Capture-Allegro interface.

Solution: In cases where your design library includes the DEVICE property (an anachronism from previous releases), you can avoid having to remove the property from each part in your library by employing the IGNORE_PROP property. To ignore the DEVICE property on a complete design, define IGNORE_PROPR as an environmental/system variable and assign it a value of "DEVICE."

As with all environmental variables, IGNORE_PROP is specific to a system login. You must have administrative privileges to define IGNORE_PROP as a system variable. Also, you must restart Capture in order to read the new variable settings.

翻译过来:

描述:在之前的版本中使用的 DEVICE 属性,在 Capture 14.0 及更高版本中用法不同。然而,在你的设计库中保留此属性可能会引起 Capture-Allegro 接口的问题。

解决方案:如果你的设计库中包含 DEVICE 属性(这是以前版本的遗留问题),你可以通过使用 IGNORE_PROP 属性来避免需要从库中的每个部件中移除此属性。为了在设计全局中忽略 DEVICE 属性,你可以将 IGNORE_PROP 定义为环境/系统变量,并将其值设置为“DEVICE”。

与所有环境变量一样,IGNORE_PROP 是针对特定系统登录的。你需要具有管理员权限才能将 IGNORE_PROP 定义为系统变量。此外,你必须重新启动 Capture 以读取新的变量设置。

是需要配置环境变量忽略此“Device”字段,就可以避免这个问题,操作如下

1)Windows控制面板设置环境变量

2)增加变量“ignore_prop”,值为“device”

3)重启电脑或者注销重新登录

4)解决!

三、其他解决方法

删除device这个字段描述,也可以解决该问题;