File Transport Over MODBUS (FOM)
1. Use function code 0x17
2. Use relative address
3. Register description
Command Register (0x0000)
#define SOH 0x01
#define STX 0x02
#define EOT 0x04
#define CA 0x18
#define C 0x43
#define NAK 0x15
Sequence Register (0x0001)
Data Register (0x0002~0x0401)
4. Sequence diagram
4.1 Write File
Write Command+Sequence+Data Register, Read Command Register by MODBUS 0x17 code
4.2 Read File
Write Command+Sequence Register, Read Command+Sequence+Data Register by MODBUS 0x17 code