测量配置包括以下的参数:
1. Measurement objects: The objects on which the UE shall perform the measurements.
- For intra-frequency and inter-frequency measurements a measurement object is a single E-UTRA carrier frequency. Associated with this carrier frequency, E-UTRAN can configure a list of cell specific offsets and a list of 'blacklisted' cells. Blacklisted cells are not considered in event evaluation or measurement reporting.
- For inter-RAT UTRA measurements a measurement object is a set of cells on a single UTRA carrier frequency.
- For inter-RAT GERAN measurements a measurement object is a set of GERAN carrier frequencies.
- For inter-RAT CDMA2000 measurements a measurement object is a set of cells on a single (HRPD or 1xRTT) carrier frequency.
NOTE 1: Some measurements using the above mentioned measurement objects, only concern a single cell, e.g. measurements used to report neighbouring cell system information, serving cell UE Rx- Tx time difference.
2. Reporting configurations: A list of reporting configurations where each reporting configuration consists of the following:
- Reporting criterion: The criterion that triggers the UE to send a measurement report. This can either be periodical or a single event description.(周期性的或是基于事件的报告)
- Reporting format: The quantities (rsrp/rsrq)that the UE includes in the measurement report and associated information (e.g. number of cells to report).
3. Measurement identities: A list of measurement identities where each measurement identity links one measurement object with one reporting configuration. By configuring multiple measurement identities it is possible to link more than one measurement object to the same reporting configuration, as well as to link more than one reporting configuration to the same measurement object. The measurement identity is used as a reference number in the measurement report.
4. Quantity configurations: One quantity configuration is configured per RAT type. The quantity configuration defines the measurement quantities and associated filtering used for all event evaluation and related reporting of that measurement type. One filter can be configured per measurement quantity.
5. Measurement gaps: Periods that the UE may use to perform measurements, i.e. no (UL, DL) transmissions are scheduled.
测量结束后才会进行triger评估
下面是一个配置和报告的实例:
配置RRCConnectionReconfiguration
2016 Apr 27 10:40:59.212 [F9] 0xB0C0 LTE RRC OTA Packet -- DL_DCCH / RRCConnectionReconfiguration
Pkt Version = 8
RRC Release Number.Major.minor = 10.7.2
Radio Bearer ID = 1, Physical Cell ID = 198
Freq = 38950
SysFrameNum = N/A, SubFrameNum = 4
PDU Number = DL_DCCH Message, Msg Length = 55
SIB Mask in SI = 0x00
Interpreted PDU:
value DL-DCCH-Message ::=
{
message c1 : rrcConnectionReconfiguration :
{
rrc-TransactionIdentifier 2,
criticalExtensions c1 : rrcConnectionReconfiguration-r8 :
{
measConfig
{
measObjectToAddModList
{
{
measObjectId 1,
measObject measObjectEUTRA :
{
carrierFreq 38950,
allowedMeasBandwidth mbw100,
presenceAntennaPort1 FALSE,
neighCellConfig '01'B,
offsetFreq dB0,
cellsToAddModList
{
{
cellIndex 1,
physCellId 198,
cellIndividualOffset dB0
},
{
cellIndex 2,
physCellId 200,
cellIndividualOffset dB-1
},
{
cellIndex 3,
physCellId 476,
cellIndividualOffset dB-1
},
{
cellIndex 4,
physCellId 199,
cellIndividualOffset dB-1
},
{
cellIndex 5,
physCellId 475,
cellIndividualOffset dB-2
}
}
}
}
},
reportConfigToAddModList
{
{
reportConfigId 1,
reportConfig reportConfigEUTRA :
{
triggerType event :
{
eventId eventA3 :
{
a3-Offset 2,
reportOnLeave FALSE
},
hysteresis 4,
timeToTrigger ms320
},
triggerQuantity rsrp,
reportQuantity sameAsTriggerQuantity,
maxReportCells 4,
reportInterval ms240,
reportAmount infinity
}
},
{
reportConfigId 2,
reportConfig reportConfigEUTRA :
{
triggerType event :
{
eventId eventA2 :
{
a2-Threshold threshold-RSRP : 16
},
hysteresis 2,
timeToTrigger ms640
},
triggerQuantity rsrp,
reportQuantity both,
maxReportCells 1,
reportInterval ms480,
reportAmount r1
}
},
{
reportConfigId 3,
reportConfig reportConfigEUTRA :
{
triggerType event :
{
eventId eventA1 :
{
a1-Threshold threshold-RSRP : 45
},
hysteresis 0,
timeToTrigger ms640
},
triggerQuantity rsrp,
reportQuantity both,
maxReportCells 1,
reportInterval ms480,
reportAmount r1
}
},
{
reportConfigId 4,
reportConfig reportConfigEUTRA :
{
triggerType event :
{
eventId eventA2 :
{
a2-Threshold threshold-RSRP : 41
},
hysteresis 0,
timeToTrigger ms640
},
triggerQuantity rsrp,
reportQuantity both,
maxReportCells 1,
reportInterval ms480,
reportAmount r1
}
}
},
measIdToAddModList
{
{
measId 1,
measObjectId 1,
reportConfigId 1
},
{
measId 2,
measObjectId 1,
reportConfigId 2
},
{
measId 3,
measObjectId 1,
reportConfigId 3
},
{
measId 4,
measObjectId 1,
reportConfigId 4
}
},
quantityConfig
{
quantityConfigEUTRA
{
filterCoefficientRSRP fc6,
filterCoefficientRSRQ fc6
}
},
s-Measure 0,
speedStatePars release : NULL
}
}
}
}
*QCAT Parsing Result*
MeasurementReport
2016 Apr 27 10:40:59.864 [3B] 0xB0C0 LTE RRC OTA Packet -- UL_DCCH / MeasurementReport
Pkt Version = 8
RRC Release Number.Major.minor = 10.7.2
Radio Bearer ID = 1, Physical Cell ID = 198
Freq = 38950
SysFrameNum = N/A, SubFrameNum = 0
PDU Number = UL_DCCH Message, Msg Length = 4
SIB Mask in SI = 0x00
Interpreted PDU:
value UL-DCCH-Message ::=
{
message c1 : measurementReport :
{
criticalExtensions c1 : measurementReport-r8 :
{
measResults
{
measId 3,
measResultPCell
{
rsrpResult 66,
rsrqResult 28
}
}
}
}
}
*QCAT Parsing Result*