电量计导致的安卓开机一半自动关机故障

乘着正在启动没有熄火的时间内,赶紧在AS下adb logcat -b,看了下最后几行

09-04 16:53:01.246   466   970 I ShutdownThread: Performing low-level shutdown...
09-04 16:53:01.255     0     0 I init    : Received sys.powerctl='shutdown,thermal,battery' from pid: 466 (system_server)
09-04 16:53:01.255     0     0 I init    : sys.powerctl: do_shutdown: 0 IsShuttingDown: 0
09-04 16:53:01.255     0     0 I init    : Got shutdown_command 'shutdown,thermal,battery' Calling HandlePowerctlMessage()
09-04 16:53:01.261     0     0 I init    : starting service 'blank_screen'...
09-04 16:53:01.272     0     0 I init    : Clear action queue and start shutdown trigger
09-04 16:53:01.274     0     0 I init    : Entering shutdown mode
09-04 16:53:01.278     0     0 I init    : processing action (shutdown_done) from (<Builtin Action>:0)
09-04 16:53:01.280     0     0 I init    : Reboot start, reason: shutdown,thermal,battery, reboot_target:
09-04 16:53:01.280     0     0 I init    : Shutdown timeout: 3000 ms
09-04 16:53:01.280     0     0 I init    : Create reboot monitor thread.

shutdown,thermal,battery说明是电池过热。

回想起来板子用了一颗CW2017,今天把电池插错了,电池正接到了板子负极,电池负接到了电量计TS,虽然很快就意识到错误并断开了连接,并且后来还一度运行了一段时间,但是重启后就一直故障了,那肯定就是电量计TS脚烧了。

断开CW2017的VCC后,可以正常开机。