fixed size of 8 bytes (SDP/END + 6 bytes / SDP*2 + 6 bytes: DLLP type 1B + 3B + 2B CRC)
no target or routing information
DLLPs not subject to flow control
DLLPs no acknowledgement (time-out mechanisms)
16 bits CRC
LCRC 32-bit
Gen 1,2, SDP/END
Gen3, 2-byte SDP Token is added to the front, no END
4 DLLP group:
ACK/NAK
PM: POWER MANAGEMENT
VS: VENDOR SPECIFIC
FC: FLOW CONTROL