[转]or cad drc 错误

本文转自

恋上姐的博客

 

用“取缔”一词,是源自《嘻哈四重奏》里面卢导的口头禅,哈哈借用一下!大多数DRC warning甚至某些error可以忽略不计,不影响生成网表,但是要想成为一名成熟的电子工程师,你可以忽略某些错误,但是必须懂得为什么会产生这些错误,如何取缔掉这些错误,这样才能控制这些错误的作用范围,不致影响系统整体的设计。

1、养成好习惯,先做Annotate,后做 ERC 检查,避免元器件重名;

 

2、切记不要随意从其他page中拷贝元器件,这样容易在ERC检查时导致以下三个错误:

例如从

 
or <wbr>cad <wbr>drc <wbr>错误

 这个图(来源于另一个page)中拷贝C209这个电容到下面page中,ERC检查出现了以下三个错误:

ERROR:  [DRC0010] 

Duplicate reference

C209

 

 
or <wbr>cad <wbr>drc <wbr>错误
 

 

ERROR:  [DRC0031] 

Same Pin Number connected to  more than one net.

Ctrl_ultrasound_launch/C209/1 Nets: 'GND' and '5V_A4'.

 

 

 
or <wbr>cad <wbr>drc <wbr>错误
 

 

ERROR:  [DRC0031] 

Same Pin Number connected to  more than one net.

Ctrl_ultrasound_launch/C209/2 Nets: '9V_A1' and 'GND'.

 

 
or <wbr>cad <wbr>drc <wbr>错误
 

 

 

解决方法:先做annotate,所有元器件重新编号,再做ERC检查,这样避免不同页面元器件重名而导致网络连接在一起,可以直接解决以上3个错误!

 

 

WARNING: [DRC0003]    

Port has a type which is inconsistent with other ports on the net TMCL

解决方法:Net TMCL两端的端口类型冲突,修改一下type就好了!

 

ERROR:  [DRC0004] 

Possible pin type conflict

U5,Vout Output Connected to Power

or <wbr>cad <wbr>drc <wbr>错误

解决方法:把芯片的pintype由output换成passive

 

 

 

 

WARNING: [DRC0004]    

Possible pin type conflict E2,1 Bidirectional Connected to Output: BENCH, C (0.40, 10.10)

or <wbr>cad <wbr>drc <wbr>错误

解决方法:

These errors are produced based on the settings in the ERC matrix. If you've finished your design and you think that the connections are correct after you've checked all these errors, you can change the settings in the ERC matrix to remove them from the Design Rules Check.

To change the ERC matrix:

1.     Select the schematic page in the Project Manager.

2.     Choose Design Rules Check from the Tools menu, then select the ERC matrix tab.

3.     Make changes to the matrix, then click OK. When you click OK, Design Rules Check will run with the new settings.

     简单来说就是修改ERC matrix,来控制ERC检查,这样就提高了容错能力,更容易通过, 但前提是对自己的设计要有把握,确保正确。

 

WARNING: [DRC0006]    

Net has fewer than two connections A01

解决方法:网络标号只有一处,没有配对的,或者网络标号命名有差别,注意必须命名相同才表示连接。

 

 

 

WARNING: [DRC0006] 

Net has fewer than two connections

5V_A2

or <wbr>cad <wbr>drc <wbr>错误

 

解决方法:这个warning的产生在于一页原理图上电源bar只有一次连接点,这样就会报

 

 

错,通常可以忽略,或者在芯片的电源引脚旁边加一个0.1uF的  bypass   电容 接地就

 

 

OK,这种设计习惯也是比较好的,只要名称相同,不同页的电源bar就是相连的。

 

ERROR: [DRC0007]    

Net has no driving source A01-PC

解决方法: 总线网络标号有问题,即总线的标号必须与总线名中的一致,例如总线名为:A[0..5],那么总线的分支网络标号就只能取A0、A1、……A5中间的一部分或者全部,而不能超出或者改成其他的。

 

 WARNING: [DRC0008]

Two nets in the same schematic have the same name, but there is no off-page connector--〉

解决方法:you label a port or off-page connector with a name that is used by a power symbol or power pin on the schematic. It would be best to replace the port with a power symbol to transfer power through the design. If you have verified that there are no connectivity problems when running the netlist, you can ignore this warning.

 

ERROR: [DRC0026]

This reference has already been assigned to a different package type. U1

解决方法:检查U1各个部分part reference还有 封装有没有不同的

 

 

ERROR:   [DRC0027]    

Other parts in this package have different values or PCB footprints. U1--〉

解决方法:检查U1各个部分part reference还有 封装有没有不同的

 

 

 

ERROR:   [DRC0029] 

Bus has no name and therefore defines no signals.

N9792615

 

or <wbr>cad <wbr>drc <wbr>错误

 

解决方法:再总线上加上总线名称即可消除两端的DRC错误,总线命名必须和总线两端的的分支网络名相一致,即必须是分支网络名称的集合。

 

如果在原理图中Ctrl+F找不到出现DRC错误的Net,或出现DRC错误的Net的坐标超出图纸范围,则应把原理图的Page Size放大,有可能是因为当初画图时某些器件忘记删掉就直接调整图纸大小了。。。确实很低级的错误 

 

这篇东西也参考了网上很多文章和论坛里面的一些问题和解答,由于自己做得辛苦,所以就综合一下子,结合自己的理解和过程,希望初学的朋友不再对DRC检查迷茫,当然这些内容也不全,后续碰到了其他warning和error再补上来 。

  • 2
    点赞
  • 1
    收藏
    觉得还不错? 一键收藏
  • 0
    评论
PG/PC接口尚未被分配任何接口参数。这句话可能是指在某个程序或系统中,PG/PC接口没有配置或指定任何接口参数。 PG/PC接口是用于连接传感器、计算机和控制设备的接口。它负责传输数据和指令,使计算机能与控制设备进行通信。 在许多现代自动化系统中,PG/PC接口通常需要配置一些参数,例如通信速率、数据格式或其他相关设置。这些参数的配置可能需要根据实际的系统需求进行设置或调整。 然而,如果在某个系统中出现“PG/PC接口尚未被分配任何接口参数”的错误提示,可能有以下几种可能的原因: 1. 配置问题:系统可能没有正确配置PG/PC接口的参数。这可能是由于未正确设置或未完成设置步骤。 2. 连接问题:可能是由于接口之间的连接问题导致的。这可能是由于接口线松动、接头问题或连接错误引起的。 3. 软件问题:可能是由于软件配置问题导致的。这可能是由于软件的设置错误、版本不匹配或其他软件相关问题引起的。 为了解决这个问题,我们可以尝试以下几个步骤: 1. 检查参数配置:检查系统配置中的PG/PC接口设置,确保参数被正确设置,并且符合系统需求。 2. 检查连接:检查PG/PC接口线的连接状态,确保线材连接稳固,接头没有松动或脏污。 3. 检查软件设置:检查软件设置中的PG/PC接口选项,确保所使用的软件版本与硬件兼容,并且设置没有错误。 如果以上步骤无法解决问题,可能需要进一步检查硬件设备和系统软件是否有其他问题,并可能需要与供应商或技术支持部门联系以获取进一步的帮助。最重要的是,确保从可靠的来源获取支持和解决方案。

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值