为了改进用于粘膜下肿瘤/疾病的诊断准确度,我们提出一个磁驱动的软体机器胶囊机器人,它使用细针活检技术取得活检样本在一个胃的一块深度组织中。我们展示用于细针活检胶囊机器人的设计,控制和人机交互理论。
To improve their diagnostic accuracy for submucosal tumors / diseases, we propose a magnetically actuated soft robotic capsule robot, which takes biopsy samples in a deep tissue of a stomach using the fine-needle biopsy technique. We present the design, control and human-machine interfacing methods for the fine-needle biopsy capsule robot.

1. 定位和驱动系统的设计和制造 design and fabrication of localizaiton and actuation system

一个自定义的磁驱动和定位系统被设计并建立来表现运动为了机器人。系统的主要要求是有足够的工作空间(10厘米直径和5厘米深度),用于朝向控制的足够的力矩(10毫牛米),和用于坍塌运动的足够的力(0.6牛)。驱动系统有九个电磁线圈。驱动系统的配置与之前报告的磁驱动系统不同来容纳大的工作空间。配置被优化来最小化在定位系统的磁场并且产生一个强的磁场梯度指向线圈的一般方向。系统利用磁场的不均一性,在磁场中磁势能阱被简单地创造在工作区域中为了控制目的。
A custom magnetic actuation and localization system is designed and built to perform the motions for the robot. The main requirement of the system is to have enough working space (10 cm diameter and 5 cm depth), enough torque for the orientation control (10 mN ⋅ \cdot M), and enough force for the collapsing motion (0.6N). The actuation system has 9 electromagnetic coils. The configuration of the actuation system is different from previously reported magnetic driving systems to accommodate the large working space. The configuration is optimized to minimize the magnetic field on the localization system and to generate a strong magnetic field gradient torwards the general direction of the coils. The system exploits nonuniformity of the magnetic field where the magnetic potential energy wells are easily created in the working space for the control purpose.

2. 机器人控制运动 robot controlled motions

机器人在胃中导航,使用滚动运动并控制朝向。对于活检来说,机器人锚定于一个SMT的顶点并且插入活检针在SMT组织中,使用多次坍塌动作。机器人的朝向被施加的一个特定磁场和它的梯度控制。通过设定在机器人上的侧边力为0并且最小化在2D上机器人周围的磁力的改变,作用于机器人的磁力的影响被最小化了。这使得机器人控制鲁棒对于2D侧边定位误差和机器人位置的快速改变。滚动运动是朝向控制的一个拓展。通过滚动胶囊期望朝向,机器人在胃的表面滚动并移动到其他的地方。机器人能容易地滑下瘤当一个下落力,比如重力,被施加。这是因为磁力矩不能被施加沿着磁矩的轴;因此,机器人会绕轴旋转并滑下瘤。这个问题能被处理通过在瘤的中心的2D侧位置创造一个相对强的磁能量。机器人执行这个动作(坍塌)在瘤锚定动作之后。
The robot navigates inside the stomach using rolling locomotion and controls the orientation. For biopsy, the robot anchors on top of a SMT and inserts the biopsy needle inside the SMT tissue using the collapsing motion several times. The robot’s orientation is controlled by applying a specific magnetic field and its gradient. By setting the lateral force on the robot as 0 and minimizing the change of magnetic force around the robot in 2D, the effect of the magnetic force on robot is minimized. This makes the robot control robust to the 2D lateral localization error and fast change of the position of the robot. The rolling locomotion is an extension of the orientation control. By rolling the desired orientation of the capsule, the robot rolls on the surface of the stomach and translates to another location. The robot can easily roll off the tumor when a downward force, such as the gravity, is applied. This is because the magnetic torque can not be applied along the axis of the magnetic moment; therefore, the robot can rotate about this axis and roll off the tumor. This problem is handled by creating a relatively strong magnetic energy well in 2D lateral position at the center of the tumor. The robot performs this motion (collapse) after the tumor anchoring motion.

3. 磁场生成 magnetic field generation

磁场和它的梯度通过单独线圈的贡献的叠加被生成。每个电磁铁的磁场被建模为一个磁极子。通过叠加磁场和梯度,我们能找到用于磁场,梯度和力的映射。磁场能被表达为:
The magnetic field and its gradient are generated by the superposition of individual coils’ contribution. The magnetic field of each electromagnet is modeled as a magnetic dipole. By superimposing the magnetic field and the gradient, we can find maps for magnetic field, gradient and force. The magnetic field could be expressed as:

b = B ( r ) I \textbf{b}=\mathbb{B}(\mathbf{r})\mathbf{I} b=B(r)I

磁场梯度能被描述为:
The magnetic field gradient is described as:

h = G ( r ) I \textbf{h}=\mathbb{G}(\mathbf{r})\mathbf{I} h=G(r)I

与其他映射相似,磁力能被表达为:
Same as the other mappings, the magnetic force is expressed as:

f = F ( r , n ^ ) I \textbf{f}=\mathbb{F}(\mathbf{r,\hat{n}})\mathbf{I} f=F(r,n^)I

I \mathbf{I} I是流荡在每个线圈上的电流。 B \mathbb{B} B是磁场映射矩阵。 G \mathbb{G} G是磁场导数映射。 F \mathbb{F} F是力映射矩阵。 n ^ \mathbf{\hat{n}} n^是朝向向量,它表示胶囊的头朝向。

4. 控制理论 control methods

胶囊机器人通过非均匀磁场被控制。线圈的被测稳定时间(有一个磁芯的存在)是0.1s。相对地,机器人的系统动态是快速的因为低质量和低惯性矩。因此,我们好好使用磁能量用于控制机器人,它展现了开环的稳定的行为。
有三种不同的控制器基于在robot controlled motions章节中展示的不同的运动。一个高等级比例积分控制器被使用通过反馈来闭上开环控制器。
The capsule robot is controlled by the non-uniform magnetic field. The measured settling time of the coil ( with the presence of a magnetic core ) was 0.1s. Relatively, the system dynamics of the robot is fast due to the low mass and low moment of inertia.Thus, we utilized the magnetic energy well for controlling the robot, which showed open-loop stable behaviors.
There are three different controllers based on the different motions presented in the robot controlled motions section above. A high-level PI controller is used to close the open-loop controllers with feedback.

4.1 开环朝向控制器 open-loop orientation controller

我们将控制分离为两个部分:用于重力消除的磁场和用于朝向控制的磁场。
We seperate the control in two parts: the magnetic field for gravity cancellation and the magnetic field for the orientation control.

被施加到倒立摆的重力通过一个静态磁场被消除。
The gravity applied to the inverted pendulum is cancelled by a static magentic field.

n ^ L × m g + M n ^ × b c = 0 → b c = − m g M \mathbf{\hat{n}} L \times m \mathbf{g} + M \mathbf{\hat{n}} \times \mathbf{b}_{c} = 0 \rightarrow \mathbf{b}_{c} = -\frac{m \mathbf{g}}{M} n^L×mg+Mn^×bc=0bc=Mmg

L是从枢纽点到质量中心的距离。通过分离重力的影响,调节机器人朝向的磁场,就简单是与所需方向相同方向的B场。用于朝向调整的B场是:
By seperating the effect of t