What's the ZQ Calibration command?
It's used to calibrate DRAM Ron & ODT values. In normal operation, the DDR3 SDRAM needs longer time to calibrate output driver and on-die termination circuits at initialization and relatively smaller time perform periodic
calibrations.
There are two parameters exisited in the ZQ calibration commands. ZQCL and ZQCS.
ZQCL is used to perform the initial calibration during power-up initialization sequences. other is used to perfor periodic calibrations to account for voltage and temperature variations.
ZQCL can be issued at anytime, it's up to the controller and the system enviroment. if the calibration finished, the calibrated values are transferred from the calibration engine to DRAM IO, which gets reflected a updated
output driver and on-die termination values.
ZQCS, It accurately correct the a minimum of 0.5%(ZQ correction) of RON and RTT impedance error withiin 64 nCK for all speed bins assuming the maximum sensitivities specified in the 'Output Driver Voltage and Temperature
Sensitivity' and 'ODT Voltage and Temperature Sensitivity' tables. we can caculate it by the formula.
the spec give us a eg.
ZQcorrection / [ ( Tsens * Tdriftrate) + (Vsens * Vdriftrate)]
if Tsens = 1.5% per degress, Vsens = 0.15% per MicroVoltagem, Tdriftrate = 1 degree per Sec and Vdriftrate = 15 microVoltage per sec. So the interval between ZQCS command is calcuated as : 0.5/ [(1.5 * 1) + (0.15 * 15)]
= 0.133ms
ZQ pin needs external resistor, it should be tied throught a resister (240 ohm +/- 1%) to the ground. meanwhile, it can be share with another.
But spec told us that the total capacitive loading on the ZQ pin must be limited.