ISE调试的时候,不能光看tcl consetle,里面的叙述不全的,需要进到工程文件夹找到对应的文件,打开查看。像在map过程出错,可以查看*.map和*.mrp文件。
像在ISE窗口显示出来的是:
ERROR:Place:864 - Incompatible IOB's are locked to the same bank 1
Conflicting IO Standards are:
IO Standard 1: Name = LVCMOS33, VREF = NR, VCCO = 3.30, TERM = NONE, DIR =
OUTPUT, DRIVE_STR = 12
List of locked IOB's:
VCC1P8_EN1_p
PHY_RST_np
UCD9222_ENA1_p
UCD9222_ENA2_p
SYS_PGOOD_p
UCD9222_RST_np
PCA9306_EN_p
VCC1P5_EN_p
VCC2P5_EN_p
查看了这几个信号都没有问题。
但是在map文件中显示的是:
ERROR:Place:864 - Incompatible IOB's are locked to the same bank 1
Conflicting IO Standards are:
IO Standard 1: Name = LVCMOS33, VREF = NR, VCCO = 3.30, TERM = NONE, DIR =
OUTPUT, DRIVE_STR = 12
List of locked IOB's:
VCC1P8_EN1_p
PHY_RST_np
UCD9222_ENA1_p
UCD9222_ENA2_p
SYS_PGOOD_p
UCD9222_RST_np
PCA9306_EN_p
VCC1P5_EN_p
VCC2P5_EN_p
IO Standard 2: Name = LVCMOS18, VREF = NR, VCCO = 1.80, TERM = NONE, DIR =
OUTPUT, DRIVE_STR = 8
List of locked IOB's:
DSP_SSPMISO_p
These IO Standards are incompatible due to VCCO mismatch.
然后就可以定位到问题在于:DSP_SSPMISO_p这个信号