在家学习一下Simulink自带的异步电机模型,异步电机是双馈电机(DFIG、DFIM)的基础。
Mechanical input
Select the torque applied to the shaft or the rotor speed as a Simulink® input of the block, or to represent the machine shaft by a Simscape™ rotational mechanical port.
Select Torque Tm
(default) to specify a torque input, in N.m or in pu, and change labeling of the block input to Tm
. The machine speed is determined by the machine Inertia J (or inertia constant H for the pu machine) and by the difference between the applied mechanical torque Tm and the internal electromagnetic torque Te. The sign convention for the mechanical torque is: when the speed is positive, a positive torque signal indicates motor mode and a negative signal indicates generator mode.
Select Speed w
to specify a speed input, in rad/s or in pu, and change labeling of the block input to w
. The machine speed is imposed and the m