汇川伺服驱动器整理

额定电压(V)功率(KW)额定输入电流(A)系数乘系数电流(A)推荐断路器电流(A)
单相220V0.22.31.53.454
0.441.566
0.757.91.511.8516
19.61.514.416
1.512.81.519.220
三相220V15.11.57.6510
1.581.51216
三相380V12.41.53.64
1.53.61.55.46
25.61.58.410
381.51216
5121.51820
6161.52425
7.5211.531.532

 

额定电压(V)功率(KW)额定输入电流(A)系数乘系数电流(A)推荐接触器电流(A)
单相220V0.22.312.39
0.44149
0.757.917.99
19.619.612
1.512.8112.818
三相220V15.115.19
1.58189
三相380V12.412.49
1.53.613.69
25.615.69
38189
51211212
61611618
7.52112125

 

额定电压(V)功率(KW)额定输入电流(A)系数乘系数电流(A)推荐滤波器电流(A)
单相220V0.22.312.33
0.44144
0.757.917.98
19.619.610
1.512.8112.816
三相220V15.115.17
1.581816
三相380V12.412.47
1.53.613.67
25.615.67
381816
51211216
61611616
7.52112130

 

额定电压(V)功率(KW)额定输入电流(A)系数乘系数电流(A)推荐保险丝电流(A)
单相220V0.22.336.915
0.4431220
0.757.9323.735
19.6328.840
1.512.8338.440
三相220V15.1420.450
1.5843250
三相380V12.437.215
1.53.6310.820
25.6316.820
3843250
51244850
61646470
7.521484125

 

磁环(绕三匝)电源线